13.5 Transfer Data Length Change Function
The transfer data length of CSIB can be changed from 8 to 16 bits in 1-bit units by using the CBnCL3 to
CBnCL0 bits of the CBnCTL2 register.
If a transfer data length of other than 16 bits is specified, set data in the CBnTX or CBnRX register, jus-
tifying to the least significant bit, regardless of whether the first transfer bit is the MSB or LSB. Any data
can be set to the higher bits that are not used, but the receive data is 0 after serial transfer.
Downloaded from
Elcodis.com
electronic components distributor
Chapter 13 3-Wire Serial Interface (CSIB)
Figure 13-8: Changing Transfer Data Length
(a) When transfer bit length = 10 bits, MSB first
SOBn
15
10
(b) When transfer bit length = 12 bits, LSB first
SIBn
15
12
11
Insert 0
User's Manual U16702EE3V2UD00
9
Insert 0
SIBn
0
SOBn
0