Figure 60 Port Interface; Table 29 Port Parameters - Honeywell Performance Series User Manual

Embedded network video recorder
Hide thumbs Also See for Performance Series:
Table of Contents

Advertisement

1. Go to Main Menu > Network > Port.

Figure 60 Port Interface

2. Configure the settings for the connection parameters.
Note: The connection parameters except Max Connection cannot take
effects until the Device has been restarted.

Table 29 Port Parameters

Parameter
Max Connection
TCP Port
UDP Port
HTTP Port
RTSP Port
POS Port
HTTPS Enable
HTTPS Port
3. Click Apply to complete the settings.
58
The Port interface is displayed.
Description
The allowable maximum clients accessing the Device at the same time,
such as WEB, Platform, and Mobile Phone.
Select a value between 1 and 128. The default value setting is 128.
The default value setting is 37777. You can enter the value according to
your actual situation.
The default value setting is 37778. You can enter the value according to
your actual situation.
The default value setting is 80. You can enter the value according to your
actual situation.
If you enter other value, for example, 70, and then you should enter 70
after the IP address when logging in the Device by browser.
The default value setting is 554. You can enter the value according to
your actual situation.
Data transmission. The value range is from 1 through 65535. The default
value is 38800.
Enable HTTPS.
HTTPS communication port. The default value setting is 443. You can
enter the value according to your actual situation.
Performance Series Embedded NVR User Guide