Parameter
LED
Tray Icon
Hide
Password
Admin
Password
Auth Timeout
Certs Path
Ping Payload
Ping Timeout
ms
Ping Delay
ms
Note: Tap the Commit button to save changes. If this panel is closed before tapping the Commit
button, changes are not saved!
314
Default
Function
Off
The LED on the wireless card is not visible to the user when the
wireless card is installed in a sealed mobile device.
Options are: On, Off.
This parameter cannot be changed.
On
Determines if the Summit icon is displayed in the System tray.
Options are: On, Off
On
When On, the Summit Config Utility masks passwords (characters
on the screen are displayed as an *) as they are typed and when
they are viewed. When Off, password characters are not masked.
Options are: On, Off.
SUMMIT
A string of up to 64 alphanumeric characters that must be entered
(or Blank)
when the Admin Login button is tapped. If Hide Password is On,
the password is masked when typed in the Admin Password Entry
dialog box. The password is case sensitive. This value is masked
when the Admin is logged out.
Options are: none.
8 seconds
Specifies the number of seconds the Summit software waits for an
EAP authentication request to succeed or fail.
If the authentication credentials are stored in the active profile and
the authentication times out, the association fails. No error
message or prompting for corrected credentials is displayed.
If the authentication credentials are not stored in the active profile
and the authentication times out, the user is again prompted to
enter the credentials.
Options are: An integer from 3 to 60.
System
A valid directory path, of up to 64 characters, where WPA
Certificate Authority and User Certificates are stored on the mobile
device when not using the Windows certificates store. Ensure the
Windows folder path exists before assigning the path in this
parameter. See
User Certificates. This value is masked when the Admin is logged
out.
Options are: none.
For example, when the valid certificate is stored as My Computer/
System/MYCERTIFICATE.CER, enter System in the Certs Path text
box as the Windows folder path.
32 bytes
Maximum amount of data to be transmitted on a ping.
Options are: 32 bytes, 64, 128, 256, 512, or 1024 bytes.
5000
The amount of time, in milliseconds, that a device will be
continuously pinged. The Stop Ping button can be tapped to end
the ping process ahead of the ping timeout.
Options are: Any number between 0 and 30000 ms.
1000
The amount of time, in milliseconds, between each ping after a
Start Ping button tap.
Options are: Any number between 0 and 30000 ms.
Thor VM2 with with Microsoft Windows Embedded CE 6.0 User Guide