Honeywell Thor VM2 User Manual page 208

Vehicle-mounted computer with microsoft windows embedded ce 6.0
Hide thumbs Also See for Thor VM2:
Table of Contents

Advertisement

Add Prefix/Suffix Control
Start > Settings > Control Panel > Data Collection tab > Symbology button
Use this option to specify a string of text, hex values or hat encoded values to be added
to the beginning (prefix) or the end (suffix) of the bar code data.
Up to 19 characters can be included in the string. The string can include any character
from the keyboard plus characters specified by hex equivalent or entering in hat encod-
ing. See
Use the Escape function to enter literal hex and hat values.
Add
Prefix
Add
Suffix
Note: Non-ASCII equivalent keys in Key Message mode are unavailable in this option. Non-ASCII
equivalent keys include the function keys (e.g. F1), arrow keys, Page up, Page down, Home,
and End.
Symbologies
The Thor VM2 supports only Custom IDs.
Ctrl Char Mapping
The Ctrl Char Mapping button (Control Character Mapping) activates a dialog to define
the operations the Data Collection Wedge performs on control characters (values less
than 0x20) embedded in bar codes.
196
the Code ID. If Strip Code ID is enabled, the data should not include the Code ID since
it has already been stripped.
Hat Encoding
for a list of characters with their hex and hat-encoded values.
To enable a prefix, check the Prefix checkbox and enter the desired string in the text box.
The default is disabled (unchecked) with a blank text string. When bar code data is processed,
the Prefix string is sent to the output buffer before any other data.
Because all stripping operations have already occurred, stripping settings do not affect the
prefix. The prefix is added to the output buffer for the Symbology selected from the pull-down
list.
If 'All' is selected, the prefix is added for any symbology that has not been specifically
configured.
To enable a suffix, check the Suffix checkbox and enter the desired string in the text box.
The default is disabled (unchecked) with a blank text string. When bar code data is processed,
the Suffix string is sent to the output buffer after the bar code data.
Because all stripping operations have already occurred, stripping settings do not affect the
suffix. The suffix is added to the output buffer for the Symbology selected from the pull-down
list.
If 'All' is selected, the suffix is added for any symbology that has not been specifically
configured.