Honeywell Thor VM2 User Manual page 253

Vehicle-mounted computer with microsoft windows embedded ce 6.0
Hide thumbs Also See for Thor VM2:
Table of Contents

Advertisement

UPS Mode
This mode is selected any time external power is not present, regardless of selected
Power Configuration. Ignition Input is ignored.
Thor VM2 is Off
Conditions
Result
The Thor VM2 boots and follows the UPS power scheme with power management tim-
ers reset at boot up.
Conditions
The Thor VM2 is Off and the power button is pressed the Thor VM2 and at least one of
the following conditions are met:
Results
The Thor VM2 remains Off.
Thor VM2 is On
Conditions
The Thor VM2 is On and external power is removed, such as:
Result
The Thor VM2 continues to run and follows the UPS mode power scheme with power
management timers reset at the time of power removal. UPS charging is disabled.
Thor VM2 with with Microsoft Windows Embedded CE 6.0 User Guide
The Thor VM2 is Off and the power button is pressed the Thor VM2 and both the
following conditions are met:
UPS power is over 10% capacity
CPU temperature is over 20ºC
UPS power is under 10% capacity
CPU temperature is under 20ºC
Thor VM2 is removed from a powered dock (Dock power switch On)
Thor VM2 is mounted to a dock and truck power is removed from the dock
Thor VM2 is mounted to a dock and the dock power switch is turned Off