Honeywell CIU 888 Configuration Manual page 97

Hide thumbs Also See for CIU 888:
Table of Contents

Advertisement

Part No.: 4417584_Rev12
Getting Started
6. Click the Level tab, the Properties detail appears.
You can view or edit these properties:
Properties
Level enabled
Negative level enabled
0.1 mm level resolution
No alarm when gauge in
test
Level address
Level TOI
Level TOR
* Refer to TABLE 3-1 for additional information.
7. Click the Water tab, the Properties detail appears.
You can view or edit these properties:
Properties
Water probe enabled
Configuration Manual
CIU 888
Description
Check to enable level scan.
Check to enable the option. This selection is only possi-
ble for gauge types 854, 872, 873, 894 and 954.
Check to enable the option. This selection is only possi-
ble if the level engineering unit is set to 'm' or 'mm' and
if the gauge type is not 811, 813, 866 or 872.
Check to disable gauge alarms during operational com-
mands.
Enter level transmission address.
Select B, C, E, or M*.
Select B, ZLQ or L (the combination of level TOR
'ZLQ' and level type 'Ullage' is not possible. With level
type 'Ullage', use level TOR 'L')*.
Description
Check to enable water level scan from external probe.
3 - 67