Honeywell CIU 888 Configuration Manual page 87

Hide thumbs Also See for CIU 888:
Table of Contents

Advertisement

TankAirDensity
WCF Method
(kg/m3)
API MPMS Ch
1.199228
11.5
Simplified
TankAirDensity
Custom
Custom
NOTE: Reference density overwrite - For the above mentioned GSV calculation types
Part No.: 4417584_Rev12
Getting Started
VapDensity
(kg/m3)
1.199228
0
Custom
Notes on GSV Calculation Type:
a) Reference density can be an input for the following tables
ASTM D 1250-80 T5/6, ASTM D 1250-80 T23/24, ASTM D 1250-80
T53/54, ASTM D 1250-80 T59/60
API MPMS Ch. 11.1 (2004) API @ 60 F (T5/6), API MPMS Ch. 11.1
(2004) RD60 @ 60 F (T23/24), API MPMS Ch. 11.1 (2004) kg/m3 @
15 C (T53/54), API MPMS Ch. 11.1 (2004) kg/m3 @ 30 C (T59/60)
ASTM-IP-52 T23/24, ASTM-IP-52 T53/54
API MPMS Ch. 11.2.4 (2007) (GPA TP-27-07) T23/24, API MPMS
Ch. 11.2.4 (2007) (GPA TP-27-07) T53/54, API MPMS Ch. 11.2.4
(2007) (GPA TP-27-07) T59/60
(Bullet point 1 to Bullet point 4), the host system should overwrite Sample
density and Sample temperature with Sample density = Desired Reference
density and Sample temperature = Product Reference temperature.
ASTM D4311-83 T1, ASTM D4311-83 T2, ASTM D4311-96 T1,
ASTM D4311-04 T1, ASTM D4311-04 T2, ASTM D4311-15 API @
60 F, ASTM D1555M-15 kg/m3 @ 15 C
LinearTCF, ManualCTL, User Configurable CTL table
EN15940-2019, SGS-2021, NBR15639-2016
Sample density and sample temperature can be input for the
following tables
b) ASTM D 1250-80 T5/6, ASTM D 1250-80 T23/24, ASTM D 1250-
80 T53/54, ASTM D 1250-80 T59/60
API MPMS Ch. 11.1 (2004) API @ 60 F (T5/6), API MPMS Ch. 11.1
(2004) RD60 @ 60 F (T23/24), API MPMS Ch. 11.1 (2004) kg/m3 @
15 C (T53/54), API MPMS Ch. 11.1 (2004) kg/m3 @ 30 C (T59/60)
Configuration Manual
CIU 888
AirBrassDensity
(Density of calibration
weights)
(kg/m3)
8000
0
Custom
Remarks
Use of the 'general' air buoy-
ancy correction equation as
detailed in OIML is equiva-
lent to the equation used in
API MPMS Ch. 11..5.3. The
derivation is even spelled out
in Annex B.5 of the same
document.
This method is 'Advanced'
and allows users/operators
to configure each of the
three inputs to any value.
3 - 57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents