Part No.: 4417584_Rev12
Getting Started
Properties
Flow calculation interval
Flow calculation damping
Flow calculation indepen-
dent of moving status
Flow trip
Note: FlowTOV is only calculated in case of 880 calculation flow.
15.Click the RIC tab, the Properties detail appears.
You can view or edit these properties:
Properties
Roof Immersion Com-
pensation
Ref. FR level sensors 1
Ref. FR level sensors 2
Ref. FR level sensors 3
Configuration Manual
CIU 888
Description
Interval Time for Flow Rate Calculation.
FlowInterval (>= 0) is the interval time, in seconds, after
which the the flow rate of TOV must be calculated
again.
Flow Interval is checked each time that the tank is cal-
culated ([ProductLevel] is measured).
Not
Flow Rate Multiplication Factor.
Damping Factor for Flow Rate Calculation.
To obtain a steady flow rate, a damping factor (0.0 <
FlowMul <= 1.0) is used.
If FlowMul = 1.0, the flow rate is not damped at all, but it
can be very unstable then.
If the flow
Bit 3 from entity 8140
Flow Rate Calculation Trip Value.
Whenever FlowTOV is calculated, the actual calculated
TOV is compared with TOV at the time of the previous
check, see FlowInterval.
If the difference exceeds the value of FlowTrip, thus
reducing the effect of external in
Description
This compensates the volume for the effects of dynamic
loads like snow, rain water on top of the floating roof.
Selection: Enable / Disable
Reference floating roof level sensors 1
Reference floating roof level sensors 2
Reference floating roof level sensors 3
3 - 46