Overview of Alarms
NCK alarms
8034
Option 'activation of axis containers' not set
Definitions:
The option for activating the axis container function in MD10002
$MN_AXCONF_LOGIC_MACHAX_TAB is not enabled.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Do not configure any containers
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
8036
Option: it is not allowed to set different IPO cycles or position control
cycles with NCU link.
Definitions:
The option for activating the FAST_IPO_LINK has not been set. For NCU link, all Ipo or position con-
trol cycles must then be equal (see FAST-IPO-LINK description).
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Buy option
- Do not activate different Ipo or position control cycles (see MD10070
$MN_IPO_SYSCLOCK_TIME_RATIO and MD10060 $MN_POSCTRL_SYSCLOCK_TIME_RATIO).
Program Con-
Switch control OFF - ON.
tinuation:
8037
'Activate APC/Number of current setpoint filters' option not set.
Definitions:
More than six current setpoint filters were activated in the drive, although the corresponding option
had not been set.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Buy option
- Deactivate the 'Advanced Positioning Control' (APC) function in the drive.
- Set a maximum of six current setpoint filters in the drive.
Program Con-
Switch control OFF - ON.
tinuation:
8038
Option 'activation of more than %1 lead link axes' not set
Parameters:
%1 = Number of axes
Definitions:
The option for the number of lead link axes does not match the number of configured axes in the
MD30554 $MA_AXCONF_ASSIGN_MASTER_NCU.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Configure fewer lead link axes
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
8040
Machine data %1 reset, corresponding option is not set
Parameters:
%1 = String: MD identifier
Definitions:
A machine data has been set that is locked by an option.
Reaction:
Alarm display.
2-80