Overview of Alarms
SINAMICS-Alarms
Remedy:
Carry out the following steps on the TM54F:
- activate the safety commissioning mode (p0010 = 95).
- start the copy function for SI parameters (p9700 = 57 hex).
- acknowledge complete data change (p9701 = AC hex).
- exit the safety commissioning mode (p0010 = 0).
- save all parameters (p0977 = 1).
- carry out safe acknowledgement (p10006).
For an internal software error (aaaa greater than zero):
- upgrade the software on the TM54F.
- contact the Hotline.
- replace the TM54F.
235052
<location>TM54F: Internal hardware fault
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
An internal software/hardware fault on the TM54F was identified.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- check the electrical cabinet design and cable routing for EMC compliance
- upgrade the software on the TM54F.
- contact the Hotline.
- replace the TM54F.
235053
<location>TM54F: Temperature fault threshold exceeded
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The temperature measured using the temperature sensing on the TM54F has exceeded the threshold
value to initiate this fault.
As fault response fail-safe input terminal signals are transferred to the motion monitoring functions.
Fault value (r0949, interpret decimal):
Only for internal Siemens troubleshooting.
Remedy:
- allow the TM54F to cool down.
- carry out safe acknowledgement (p10006).
235054
<location>TM54F: Temperature alarm threshold exceeded
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The temperature measured using the temperature sensing on the TM54F has exceeded the threshold
value to initiate this alarm.
Remedy:
- allow the TM54F to cool down.
- carry out safe acknowledgement (p10006).
235075
<location>TM54F: Internal communications
Message
%1
value:
Drive object:
A_INF, B_INF, S_INF, SERVO, TM41, TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
2-960