Remedy:
Switch off/on drive system including all DRIVE-CLiQ components.
Program Con-
Internal
tinuation:
129900
Data of passive drives are not backed up!
Definitions:
This indicates that passive drives are not backed up as well when an upgrade is made.
Reaction:
Alarm display.
Remedy:
If the drive shall be backed up as well, it must be enabled. If the note shall not be displayed again, set
the drive to "0" in machine data 30240 ENC_TYPE and 30130 CTRLOUT_TYPE.
Program Con-
Internal
tinuation:
129901
Time determination is being initialized. Please wait...
Definitions:
This indicates that the time determination is being initialized and that the operator shall not yet press
NC Start or execute other operator actions.
Reaction:
Alarm display.
Remedy:
Not necessary. After completion of the initialization, the dialog box will be faded out again automati-
cally.
Program Con-
Internal
tinuation:
129902
Recorded data are being processed. Please wait...
Definitions:
This indicates that data recorded by time determination are currently processed and that the operator
shall not yet press NC Start or execute other operating actions.
Reaction:
Alarm display.
Remedy:
Not necessary. After completion of the initialization, the dialog box will be faded out again automati-
cally.
Program Con-
Internal
tinuation:
129903
Time determination is active.
Definitions:
This indicates that time determination is enabled and that the user can press NC Start.
Reaction:
Alarm display.
Remedy:
Not necessary. As soon as all channels viewed for time determination are in Reset again, this mes-
sage will be cancelled automatically.
Program Con-
Internal
tinuation:
129904
%1: Current NCK Version %2 is too low for time measurement. Version
500000 or higher will be required.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
%2 = Current NCU version
Definitions:
The version of the specified NCU is too old (< 500000).
Remedy:
Upgrade or replace the relevant NCU for the required software version in order to use the time deter-
mination.
129905
%1: Unable to determine the NCK version for time measurement.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The version of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129906
%1: Unable to determine the number of channels.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The number of channels of the specified NCU could not be determined.
Remedy:
Connect to the NCU and restart the PCU if required.
129907
%1:The max. number of channels could not be determined.
Parameters:
%1 = Name of the NCU according to NETNAMES.INI
Definitions:
The maximum number of channels of the specified NCU could not be determined.
© Siemens AG 2009 All Rights Reserved