Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61014
[Channel %1: ] Block %2: Return plane exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE72.
Remedy:
Check parameter RTP.
61015
[Channel %1: ] Block %2: Contour is not defined
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61016
[Channel %1: ] Block %2: System frame for cycles missing
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
All measuring cycles can trigger this alarm.
Remedy:
Set MD 28082: MM_SYSTEM_FRAME_MASK, Bit 5=1.
61017
[Channel %1: ] Block %2: function %4 not present in NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61018
[Channel %1: ] Block %2: function %4 not executable with NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61019
[Channel %1: ] Block %2: Parameter %4 incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE60, CYCLE63, CYCLE64, CYCLE83, CYCLE952.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.