Siemens Sinumerik 840D sl Diagnostic Manual page 315

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Definitions:
An attempt was made to use a curve table whose table number is not known in the system \par.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Change the table number in the program instruction or define the curve table with the desired table
number.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18202
[Channel %1: ] Block %2 curve table: instruction CTABEND without
CTABDEF not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The CTABEND instruction, which is used to terminate the definition, has been programmed in the pro-
gram without starting a curve table definition with CTABDEF, or the CTABDEF and CTABEND instruc-
tions were not programmed in the same program level.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove the CTABEND command or add the CTABDEF( ..) command at the appropriate program
location. The CTABDEF and CTABEND instructions must be programmed in the same program level
(main or subprogram). Start the program again.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18203
[Channel %1: ] Block %2 curve table: instruction CTABDEF not within
CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the program, the instruction CTABDEF that starts the definition of curve tables, is programmed
within the definition part of a curve table. This is not allowed, as the current curve table must be com-
pleted with CTABEND first.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove command CTABEND from program or insert instruction CTABDEF ( ..) in the relevant pro-
gram position. Instructions CTABDEF and CTABEND must be programmed in the same program level
(main program or subroutine). Restart the program.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
18204
[Channel %1: ] Block %2 curve table: instruction SUPA not within
CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
G code SUPA is not allowed for the definition of a curve table, as it triggers a preprocessing stop.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove G code SUPA from the curve table definition. If possible, use G codes G53 or G153 instead
of SUPA.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-315

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents