Overview of Alarms
NCK alarms
6583
NC system memory full
Definitions:
The DRAM file system of the system area (Siemens) is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
6584
NC memory limit TMP reached
Definitions:
The DRAM file system of the TMP (temporary) area is full. The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Increase MD18351 $MN_MM_DRAM_FILE_MEM_SIZE or switch off the precompilation of individual
or all cycles or, if need be,
delete the files in the TMP area.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
6585
NC external memory limit reached
Definitions:
The DRAM file system of the external area (execution of the external drive) is full.
The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Load the files to be executed explicitly into the NCK.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
6693
File %1 lost
Parameters:
%1 = File name
Definitions:
Due to a power failure, a file change could not be terminated properly. The file is lost.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Import the file again.
Program Con-
Switch control OFF - ON.
tinuation:
6700
[Channel %1: ] Value of the machine data %2%3 is too low
Parameters:
%1 = Channel number
%2 = MD identifier
%3 = If required, field index
Definitions:
The MD28302 $MC_MM_PROTOC_NUM_ETP_STD_TYP specifies the number of default event
types for the protocol users. However, more types are used than configured.
Reaction:
Alarm display.
Remedy:
Increase MD28302 $MC_MM_PROTOC_NUM_ETP_STD_TYP.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
7000
Too many compile cycle alarms defined
Definitions:
Too many alarms are defined for the compile cycles. On powering up, the quantity was exceeded
when defining a new CC alarm.
Reaction:
Alarm display.
Remedy:
Apart from reducing the number of CC alarms, no remedial measures are possible at the present time.
(contact SIEMENS AG, System Support for A&D MC products, Hotline (Tel.: see alarm 1000)
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
2-74
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009