Siemens Sinumerik 840D sl Diagnostic Manual page 608

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
HMI-Alarms
112505
Error on interpreting contour:%n%1
Parameters:
%1 = Contour name
Definitions:
Contour is faulty.
Reaction:
NC Start disable in this channel.
Alarm display.
Remedy:
Check the contour's machining sequence.
Program Con-
Internal
tinuation:
112506
Maximum number of contour elements exceeded:%n%1
Definitions:
The maximum permissible number of 50 contour elements was exceeded when interpreting the
machining sequence of a contour.
Reaction:
Alarm display.
Remedy:
Check the contour's machining sequence and, if necessary, edit it.
Program Con-
Internal
tinuation:
112541
Program cannot be interpreted
Definitions:
The program cannot be interpreted as a ShopMill program during loading, as the program header is
missing.
Reaction:
NC Start disable in this channel.
Alarm display.
Remedy:
--
Program Con-
Internal
tinuation:
112542
GUD variable does not exist or%narray dimension too small:%1
Definitions:
The required GUD variable was not found on read or write access.
Reaction:
Alarm display.
Remedy:
Load the correct GUD variable.
Program Con-
Internal
tinuation:
112543
Prog. was created with higher software version
Definitions:
The part program has been created with a software version higher than the existing one.
Reaction:
Alarm display.
Remedy:
Delete the machining step and reprogram machining if required.
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
112544
Program cannot be opened.%nIt is already being edited.
Definitions:
Program is already open in HMI Advanced (Program or Services operating area).
Reaction:
Alarm display.
Remedy:
Close program in HMI Advanced (Program or Services operating area).
Program Con-
Clear alarm with the Delete key or NC START.
tinuation:
112546
Program cannot be opened.%nNo read access to the file.
Definitions:
The file has no write access for the current access level.
Reaction:
Alarm display.
Remedy:
Set read access with keyswitch or via password.
Program Con-
Internal
tinuation:
112550
Sequencer programming is not opened.
Definitions:
Option 'Sequencer programming' has not been set.
Reaction:
Alarm display.
Remedy:
The program is opened as G code.
2-608
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG 2009 All Rights Reserved
03/2009

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents