Overview of Alarms
NCK alarms
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61273
[Channel %1: ] Block %2: Insertion depth too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Insertion depth on chamfering too large.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Decrease the insertion depth.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61274
[Channel %1: ] Block %2: Invalid tool angle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Invalid tool angle.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check tool angle
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61275
[Channel %1: ] Block %2: Target point violates software limit switch!
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Due to a swivel action, the end point is outside the software limit switches.
Alarm triggered by following cycle: E_SP_RP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select another retraction plane or approach a suitable interpolation point.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61276
[Channel %1: ] Block %2: External tool diameter required for restrictions
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Outer tool diameter required in case of delimitations.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify the outer tool diameter.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
61277
[Channel %1: ] Block %2: Tool diameter larger than restriction
Parameters:
%1 = Channel number
%2 = Block number, label
2-490
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009