Overview of Alarms
HMI-Alarms
112605
Asynchronous subprogram was%nnot executed
Definitions:
The input values could not be correctly processed by the NC.
Reaction:
Alarm display.
Remedy:
Perform an NCK reset
Program Con-
Internal
tinuation:
112611
NC start not possible:%nDeselect single block
Definitions:
A program was activated with block search while a single block has been active.
Reaction:
Alarm display.
Remedy:
Deselect the single block.
Program Con-
Internal
tinuation:
112620
Language %1 not installed.
Definitions:
Language not installed.
Reaction:
Alarm display.
Remedy:
Install language.
Program Con-
Internal
tinuation:
112650
Unknown PLC error
Definitions:
The PLC has announced an error that is unknown in the operator panel.
Reaction:
NC Start disable in this channel.
Alarm display.
Remedy:
Press POWER ON, inform Siemens.
Program Con-
Internal
tinuation:
112999
Faulty graphic data. Exit graphic %nand restart
Definitions:
More data was generated than can be read from the operator panel.
Stop the graphic.
Remedy:
Deselect the graphic and then select it again.
113000
Invalid value - value range: %1
Parameters:
%1 = --
Definitions:
--
Remedy:
--
113001
Incorrect configuration in line %1
Parameters:
%1 = --
Definitions:
--
Remedy:
--
113002
Insufficient access level!
Definitions:
--
Remedy:
--
113003
Error when writing variable %1
Parameters:
%1 = --
Definitions:
--
Remedy:
--
113004
Insufficient dynamic memory
Definitions:
--
Remedy:
--
113005
Incorrect NC file positioning: %1
Parameters:
%1 = --