Cause:
The bypass contactor of the infeed unit was damaged by being opened (multiple number of times)
while it was conducting current.
Possible causes:
- scheduled opening under load can be necessary, for example, to protect the drive converter group
in the event of a ground fault in high frequency spindles.
- incorrect operator control of the infeed can cause the contactor to switch under load. If, in spite of a
missing operating enable, the infeed unit draws active motoring power from the DC link.
Remedy:
In order to avoid critically damaging the complete drive converter group, it is urgently recommended
to replace the damaged infeed unit.
230070
<location>Cycle requested by the power unit module not supported
Message
%1
value:
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
The following applies for CU31x and CUA31:
A cycle is requested that is not supported by the power unit.
Fault value (r0949, interpret hexadecimal):
The following applies for CU31x and CUA31:
0: The current control cycle is not supported.
1: The DRIVE-CLiQ cycle is not supported.
2: Internal timing problem (distance between RX and TX instants too low).
3: Internal timing problem (TX instant too early).
Remedy:
The following applies for CU31x and CUA31:
The power unit only supports the following cycles:
62.5 µs, 125 µs, 250 µs and 500 µs
Fault value (r0949, interpret hexadecimal):
The following applies for CU31x and CUA31:
0: Set a permitted current control cycle.
1: Set a permitted DRIVE-CLiQ cycle.
2/3: Contact the manufacturer (there is possibly an incompatible firmware version).
230071
<location>No new actual values received from the power unit module
Message
-
value:
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
The following applies for CU31x and CUA31:
More than one actual value telegram from the power unit has failed.
Remedy:
The following applies for CU31x and CUA31:
Check the interface (adjustment and locking) to the power unit.
230072
<location>Setpoints are no longer being transferred to the power unit
Message
-
value:
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
IMMEDIATELY
Cause:
The following applies for CU31x and CUA31:
More than one setpoint telegram was not able to be transferred to the power unit.
Remedy:
The following applies for CU31x and CUA31:
Check the interface (adjustment and locking) to the power unit.