Siemens Sinumerik 840D sl Diagnostic Manual page 227

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14824
[Channel %1: ] Block %2 conflict with GWPS
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The functions of constant grinding wheel surface speed GWPS and constant cutting speed G96 S...
have been activated at the same time for a spindle.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14830
[Channel %1: ] Block %2 wrong feed type selected
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
G97 has been programmed in the displayed block although G96 was not (or G97 already) active pre-
viously.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Remove G97 from the displayed block and program the correct feed type (G93, G94, G95 or G96) for
the machining section which follows.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14840
[Channel %1: ] Block %2 incorrect value range for constant cutting speed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed cutting speed is not within the input range
Input range metric: 0.01 to 9 999.99 [m/min]
Input range inch: 0.1 to 99 999.99 [inch/min]
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program cutting speed under address S within the permissible range of values.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
14850
[Channel %1: ] Block %2 changing the reference axis for a constant
cutting speed not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The attempt was made via the SCC[AX] instruction to change the reference
axis for a constant cutting speed.
This is not allowed if the indicated axis is no geometry axis.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform authorized personnel/service.
When programming SCC[AX] indicate a geometry axis known in the channel.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
NCK alarms
2-227