Siemens Sinumerik 840D sl Diagnostic Manual page 298

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
17195
Channel %1 block %2 illegal tool holder number %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Tool holder number
Definitions:
In the displayed block, a tool holder that is not defined is accessed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check the programming of the tool holder in the NC program.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
17200
[Channel %1: ] Block %2: Data of tool %3 cannot be deleted.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = T number
Definitions:
An attempt has been made to delete from the part program the tool data for a tool currently being pro-
cessed. Tool data for tools involved in the current machining operation may not be deleted. This
applies both for the tool preselected with T or that has been changed in place of another, and also for
tools for which the constant grinding wheel peripheral speed or tool monitoring is active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Check access to tool offset memory by means of $TC_DP1[t,d] = 0 or deselect tool.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
17202
[Channel %1: ] Block %2 deleting magazine data not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An attempt was made to delete magazine data which cannot currently be deleted. A magazine with
the 'tool in motion' status active cannot be deleted. A tool adapter which is currently allocated to a
magazine location cannot be deleted. A tool adapter cannot be deleted if MD18104
$MN_MM_NUM_TOOL_ADAPTER has the value -1.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
If an attempt to delete a magazine fails
$TC_MAP1[ m ] = 0 ; Delete magazine with m=magazine no.
$TC_MAP1[ 0 ] = 0 ; Delete all magazines
$TC_MAP6[ m ] = 0 ; Delete magazines and all their tools you must ensure that the magazine does
not have the 'tool in motion' status at the time of the call.
If an attempt to delete a tool adapter fails
$TC_ADPTT[ a ] = -1 ; Delete adapter with number a
$TC_ADPTT[ 0 ] = -1 ; Delete all adapters
then the data association with the magazine location or locations must first be canceled with
$TC_MPP7[ m,p ] = 0 ; m = magazine no., p = no. of the location to which the adapter is assigned.
Program Con-
Clear alarm with NC START or RESET key and continue the program.
tinuation:
2-298
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009

Hide quick links: