Siemens Sinumerik 840D sl Diagnostic Manual page 650

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
SINAMICS-Alarms
201316
<location>Drive object inactive and again ready for operation
Message
-
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
If, when inserting a component of the target topology, an inactive, non-operational drive object
becomes operational again. The associated parameter of the component is, in this case, set to "acti-
vate" (p0125, p0145, p0155, p0165).
Note:
This is the only message that is displayed for a de-activated drive object.
Remedy:
The alarm automatically disappears again with the following actions:
- activate the drive object involved (p0105 = 1).
- again withdraw the components involved.
See also: p0105 (Activate/de-activate drive object)
201317
<location>De-activated component again present
Message
-
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
If a component of the target topology for an active drive object is inserted and the associated param-
eter of the component is set to "de-activate" (p0125, p0145, p0155, p0165).
Note:
This is the only message that is displayed for a de-activated component.
Remedy:
The alarm automatically disappears again with the following actions:
- activate the components involved (p0125 = 1, p0145 = 1, p0155 = 1, p0165 = 1).
- again withdraw the components involved.
See also: p0125, p0145, p0155
201318
<location>BICO: De-activated interconnections present
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
This alarm is output:
If an inactive/non-operational drive object is again active/ready for operation
and
r9498[] or r9499[] are not empty
and
the connections listed in r9498[] and r9499 have actually been changed
Remedy:
Clear alarm:
Set p9496 to 1 or 2
or
de-activate DO again
201319
<location>Inserted component not initialized
Message
-
value:
Drive object:
A_INF, B_INF, CU_LINK, HUB, S_INF, SERVO, TB30, TM15, TM15DI_DO, TM17, TM31, TM41,
TM54F_MA, TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The inserted component has still not been initiated, as the pulses are enabled.
Remedy:
Pulse inhibit
2-650