Siemens Sinumerik 840D sl Diagnostic Manual page 641

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

03/2009
Remedy:
- insert the matching CompactFlash card
- use the matching Control Unit or power unit.
201051
<location>Drive object type is not available
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The drive object type in conjunction with the selected application-specific view is not available. The
required descriptive file (PDxxxyyy.ACX) does not exist on the CompactFlash card.
Fault value (r0949, interpret decimal):
Index of p0103 and p0107.
See also: p0103, r0103, p0107, r0107
Remedy:
- for this drive object type (p0107), select a valid application-specific view (p0103).
- save the required descriptive file (PDxxxyyy.ACX) on the CompactFlash card.
See also: p0103, r0103, p0107, r0107
201052
<location>CU: System overload calculated for the complete target
topology
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
A system overload was calculated based on a complete active target topology.
Alarm value (r2124, interpret decimal):
2: Computing time load too high.
6: Cyclic computing time load too high.
Remedy:
- reduce the sampling time.
- only use one data set (CDS, DDS).
- de-activate the function module.
- de-activate the drive object.
- remove the drive object from the target topology.
Note:
After executing the appropriate counter-measure, a new calculation must be initiated with p9974 = 1.
201053
<location>CU: System overload measured
Message
%1
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
A system overload was determined based on measured values.
Alarm value (r2124, interpret decimal):
2: Computing time load too high.
6: Cyclic computing time load too high.
See also: r9976 (System load)
Remedy:
- reduce the sampling time.
- only use one data set (CDS, DDS).
- de-activate the function module.
- de-activate the drive object.
- remove the drive object from the target topology.
201064
<location>CU: Internal error (CRC)
Message
-
value:
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
© Siemens AG 2009 All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
Overview of Alarms
SINAMICS-Alarms
2-641

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents