Overview of Alarms
NCK alarms
6030
Limit of user memory has been adapted
Definitions:
Data management checks during power-up the actually available physical user memory (DRAM,
DPRAM and SRAM) with the values in the system-specific machine data MD18210
$MN_MM_USER_MEM_DYNAMIC, MD18220 $MN_MM_USER_MEM_DPR und MD18230
$MN_MM_USERMEM_BUFFERED-USERMEM_BUFFERED.
Reaction:
Alarm display.
Remedy:
No remedial measures are required. The new maximum permissible value can be read from the
reduced machine data.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
6035
Instead of %1 KB the system has only %2 KB of free user memory of type
'%3'
Parameters:
%1 = Free memory capacity in KB defined for the control model
%2 = Actual maximum capacity of free memory in KB
%3 = Type of memory, "D" =non-battery-backed, "S" =battery-backed
Definitions:
The alarm can only occur after a 'cold start' (=NCK start-up with standard machine data). The alarm
is only a notice. There is no interference with any NCK functions. It shows that the NCK has less free
user memory available than specified by Siemens for this control variant. The value of the actually
available free user memory can also be taken from the MD18050
$MN_INFO_FREE_MEM_DYNAMIC, MD18060 $MN_INFO_FREE_MEMS_STATIC.
Siemens supplies NCK with default settings that, depending on the model, have certain (free) memory
space available for the specific settings of the actual applications. The original factory setting of NCK
systems is thus that the alarm does not occur with a cold start.
Reaction:
Alarm display.
Remedy:
Reasons for the message:
- The NCK contains compile cycle software, that uses so much memory space that the hardware can-
not provide the required memory.
- The NCK runs on hardware that is not intended for this NCK release (i.e. that has not enough mem-
ory capacity).
- If the application runs properly with the remaining free user memory (i.e. can be started up without
any errors), the message can simply be ignored.
- If the actual application cannot be configured because there is not enough memory capacity avail-
able, either the existing compile cycle must be reduced or, if possible, the system must be upgraded
with additional memory space.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
6100
Error while creating %1, error number %2 %3
Parameters:
%1 = Symbolname
%2 = Error code
%3 = If required, internal error identifier
Definitions:
An error was detected while creating a compile cycle machine data. The error number specifies the
type of error.
- Error number 1: Insufficient memory available
- Error number 2: Symbol in the NCK already exists
- Error number 3: Maximum possible number of symbols exceeded
- Error number 4: Invalid name prefix
- Error number 5: Illegal array size
Note: Other errors of this type could have occurred, but have not been displayed.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
2-60
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved