Siemens Sinumerik 840D sl Diagnostic Manual page 44

Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
Remedy:
Please inform the authorized personnel/service department.
Take greater care when optimizing the clock times MD10050 $MN_SYSCLOCK_CYCLE_TIME,
MD10060 $MN_POSCTRL_SYSCLOCK_TIME_RATIO and/or MD10070
$MN_IPO_SYSCLOCK_TIME_RATIO.
The test should be performed with an NC program that represents the highest possible control load.
To be on the safe side, a margin of 15 to 25% should be added to the times determined in this way.
Program Con-
Switch control OFF - ON.
tinuation:
4250
FastPlcCom functionality not available
Definitions:
This alarm indicates that the PLC provides the None FastPlcCom functionality during start-up
although this functionality is requested by the NCK.
Reaction:
Alarm display.
Remedy:
Retrofit the PLC with the FastPlcCom functionality or deactivate the FastPlcCom functionality by
means of NCK machine data.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4252
PLCIO read error: %1
Parameters:
%1 = PLCIO error code
Definitions:
This alarm indicates that errors occured when reading the PLCIO with the FastPlcCom functionality.
- PLC hardware does not exist
- Incorrect data transmission
- Functionality is already used by 'technological function'.
Reaction:
Alarm display.
Remedy:
Check machine data MD10394 $MN_PLCIO_NUM_BYTES_IN / MD10395
$MN_PLCIO_LOGIC_ADDRESS_IN.
Check PLC hardware configuration.
Check whether 'technological function' already uses the functionality.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
4254
PLCIO write error: %1
Parameters:
%1 = PLCIO error code
Definitions:
This alarm indicates that errors occured when writing on the PLCIO with the FastPlcCom functionality.
- PLC hardware does not exist
- Incorrect data transmission
- Functionality is already used by 'technological function'
Reaction:
Alarm display.
Remedy:
Check machine data MD10396 $MN_PLCIO_NUM_BYTES_OUT / MD10397
$MN_PLCIO_LOGIC_ADDRESS_OUT.
Check PLC hardware configuration.
Check whether 'technological function' already uses the functionality.
Program Con-
Clear alarm with the RESET key. Restart part program
tinuation:
2-44
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
© Siemens AG, 2009. All Rights Reserved
03/2009