5. WIRING OPTION
(b) Internal wiring diagram
When fabricating the cable, use the wiring diagram corresponding to the length indicated below.
MR-EKCBL20M-L
CN2, CN2A, CN2B, and
CN2C side connector
P5
1
LG
2
MR
3
MRR
4
9
BAT
Plate
SD
(Note)
MR-EKCBL20M-H
CN2, CN2A, CN2B, and
CN2C side connector
P5
1
LG
2
MR
3
MRR
4
BAT
9
Plate
SD
(Note)
Note. Always make connection for use in an absolute position detection system. Wiring is not necessary
for use in an incremental system.
Cable bending life
Standard
Long bending life
Junction
CN2, CN2A, CN2B, and
connector
CN2C side connector
7
P5
P5
8
LG
LG
MR
1
MR
2
MRR
MRR
MD
3
BAT
MDR
9
SHD
BAT
SD
Junction
CN2, CN2A, CN2B, and
connector
CN2C side connector
7
P5
P5
8
LG
LG
MR
1
MR
MRR
2
MRR
3
BAT
MD
9
SHD
MDR
BAT
SD
Applicable wiring diagram
Less than 30 m
MR-EKCBL20M-L
MR-EKCBL20M-H
5 - 14
MR-EKCBL30M-L
Junction
connector
1
7
2
8
1
3
4
2
7
4
8
5
9
3
6
Plate
9
(Note)
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Junction
connector
1
7
2
8
3
1
4
2
7
4
8
5
9
3
6
Plate
9
(Note)
30 m to 50 m
MR-EKCBL30M-L
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
P5
LG
MR
MRR
MD
MDR
BAT
CONT
SHD
P5
LG
MR
MRR
MD
MDR
BAT
CONT
SHD