4. CONNECTION OF SERVO AMPLIFIER AND SERVO MOTOR

4.3 Selection example of wires

The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
POINT
Wires indicated in this section are separated wires. When using a cable for
power line (U/V/W) between the servo amplifier and servo motor, use a 600 V
grade EP rubber insulated chloroprene sheath cab-tire cable (2PNCT). For
selection of cables, refer to app. 6.
To comply with the UL/CSA standard, use the wires shown in app. 4 for wiring.
To comply with other standards, use a wire that is complied with each standard.
Selection condition of wire size is as follows.
Construction condition: Single wire set in midair
Wire length: 30 m or less
Servo amplifier
U
V
W
Power supply
1) Servo motor power lead
2) Electromagnetic
brake lead
Encoder cable
3) Cooling fan lead
4 - 16
Servo motor
U
V
Motor
W
B1
Electromagnetic
brake
B2
Encoder
Cooling fan
BU
BV
BW