Machine Accuracies - Mitsubishi Electric HG-MR Instruction Manual

General-purpose ac
Table of Contents

Advertisement

2. INSTALLATION

2.11 Machine accuracies

The following table indicates the machine accuracies of the servo motor around the output shaft and
mounting. (except the optional products)
Accuracy [mm]
Runout of flange surface to output
shaft
Runout of fitting OD of flange surface
Runout of output shaft end
Measuring
100 × 100 or
position
less
a)
0.05
b)
0.04
c)
0.02
a) A
b)
A
c)
A
2 - 7
Flange size
176 × 176 to
130 × 130
250 × 250
0.06
0.08
0.04
0.06
0.02
0.03
280 × 280
0.08
0.08
0.03