Section D - Control and Management Interfaces

Ethernet Management Interface
Number of connectors
Type of connector
Ethernet type
Required setup
Alarm Interface
Number of outputs
Type of connector
Max. voltage
Max. current
Contact Closure Interface
Connector type
Minimum duration of event
guaranteed to be detected
Max. on generator impedance
Min. off generator impedance
Front Panel Interface
LCD
Keypad
LEDs
A-8
Item
Item
Item
Item
D9054 HDTV Encoder Installation and Operation Guide
Specification
1
Eight-pin RJ-45, MDI
10/100 Base-T
IP address, default gateway and subnet
mask
Specification
3, each having one set of contacts closed
and one set open during normal operation.
Alarms are signalled by reversing the
polarity of the two contact sets.
Terminal block
≤ 30 V AC, ≤ 30 V DC
≤ 1 A
Specification
9-pin sub-D female
250 ms, 1 frame period, e.g., for 1080i/25
Hz 40 ms for DPI applications
100 Ω
100 kΩ
Specification
2 lines of 40 characters backlit LCD.
Arrow keys, 0 to 9, Select, Menu and Prev
keys, F1 to F4
Green LED for Signal status. Red LED for
Alarm indication.