Cisco D9054 Installation And Operation Manual page 237

Hdtv encoder
Table of Contents

Advertisement

Message
Description and Remedy
H264 IP Statmux:
Description: The mainboard host
Rate Table
processor (PPC) has lost control of the
Sequence Error
communication buffers.
Remedy: If the error is not resolved
immediately, power-cycle the encoder. If
this does not correct the issue, contact the
closest Cisco customer support center for
assistance.
H264 IP Statmux:
Description: Due to an error, the encoder
Safe Rate Mode
has changed to it's default rate. This is
seamless and does not cause video hits.
The encoder will remain in CBR mode at
the default rate until the error is cleared.
H264 IP Statmux:
Description: There is more than 1 active
Service/Pid
encoder in the statmux group with the
Conflict
same video PID.
Remedy: Ensure that different video PIDs
are set for each encoder in the statmux
group.
H264 IP Statmux:
Description: The statmux rate quality
S-tick out of sync
messages arrived later than expected.
This indicates that the encoder is not
functioning in statmux mode.
Remedy: Contact the closest Cisco
customer support center for assistance.
H264 IP Statmux:
Description: A statmux tick (s-tick) rate
S-tick rate
mismatch occurred in the statmux group.
mismatch
The s-tick rate is one field in the Rate/
Quality message.
Remedy: Check that all encoders are set
to the same Statmux Clock Source. If the
clock source is set to Video, ensure that
all sources are set to the same Video
Format. If the clock source is set to
External Reference, check the reference
source.
4038938 Rev A
D9054 HDTV Encoder Intstallation and Operation Guide
Severity
Default
Alarm
Category
Minor
B
Minor
B
Minor
B
Major
A
Major
A
Enable
On
On
On
On
On