Cisco D9054 Installation And Operation Manual page 244

Hdtv encoder
Table of Contents

Advertisement

Message
Description and Remedy
System boot
Description: System boot has been
completed
completed.
Temperature
Description: The temperature is
approaching high
approaching the upper limit for safe
limit
operation.
Remedy: Apply external cooling if the
ambient temperature is above 45 degrees
Celsius. Also check that whether the
(internal) fan filter is dirty or that the four
fans appear to be operating properly.
Contact the closest Cisco customer
support center for assistance.
Temperature
Description: The temperature is
approaching low
approaching the lower limit for safe
limit
operation.
Remedy: Raise the ambient temperature
to more than 0 (zero) degrees Celsius.
Temperature
Description: The temperature is outside
outside safe limits
the safe limits. The unit will be shut
down.
Remedy: Check that the ambient
temperature is within 0 to 45 degrees
Celsius. Also check whether the (internal)
fan filter is dirty or that the four fans are
operating properly. Contact the closest
Cisco customer support center for
assistance.
The option
Description: An option license file is
import string is
invalid.
invalid
Remedy: Check the Host ID and the
ordered options in the option license file.
6-22
D9054 HDTV Encoder Intstallation and Operation Guide
Severity
Default
Alarm
Category
Information None
Warning
B
Warning
B
Critical
A
Information None
4038938 Rev A
Enable
On
On
On
On
On