Cisco D9054 Installation And Operation Manual page 243

Hdtv encoder
Table of Contents

Advertisement

Message
Description and Remedy
Power supply 1
Description: Power supply 1 has
malfunction
malfunctioned due to either (e.g.,)
internal fan failure an over-temperature
condition. Continued operation will lead
to failure.
Remedy: Replace the power supply.
Power supply 2
Description: Power supply 2 has
malfunction
malfunctioned due to either (e.g.,)
internal fan failure an over-temperature
condition. Continued operation will lead
to failure.
Remedy: Replace the power supply.
Power-up self-
Description: The internal power-up self-
test failed
test failed.
Remedy: When persistent, contact your
Cisco customer support center for
assistance.
Regulus
Description: An error was detected on the
connection error
RS-232 connection to the Regulus
Statistical Multiplex Controller.
Remedy: Check the RS-232 connection
between the Statistical Multiplex
Controller and the encoder. Consult the
manuals for information on how to
interconnect the devices.
Settings file is
Description: The received settings file
rejected
was illegal, and could therefore not be
applied.
Remedy: Evaluate settings and re-apply
when corrected.
Settings updated
Description: The settings have changed
either by a settings file import, a change
via the front panel or via ROSA/SNMP.
Statmux RS-232
Description: An error in the RS-232
interface error
statmux interface has been detected.
Remedy: Check that the RS-232 cabling is
OK and that the equipment connected to
the RS-232 interface operates as required.
4038938 Rev A
D9054 HDTV Encoder Intstallation and Operation Guide
Severity
Default
Alarm
Category
Major
B
Major
B
Critical
A
Major
B
Information None
Information None
Major
B
Enable
On
On
On
On
On
On
On
6-21