Opc Interface - Honeywell Vertex M User Manual

Continuous gas monitor
Hide thumbs Also See for Vertex M:
Table of Contents

Advertisement

LED Label
GW Status
MS
Ch. A and Ch. B
Ch. A or Ch. B
MO

8.8.9 OPC Interface

The Vertex M presents the gas alarm, fault status and gas concentration using OPC interface.
The OPC services by FactoryTalk Linx Gateway are automatically initialized at startup of the
application, enabling the Vertex M to act as an OPC Server. The user may connect to the
Network interface Cards RJ45 Port at the rear of the data Acquisition System. See "Data
Acquisition Computer (rear)" on page  19 for more information. The Vertex M contains 1331
OPC tags as listed in Table 8-7. Tag Names. Many of these are present for historical reasons
and have low utility for an external HMI system. The column "recommended for most HMI
systems" is provided to help separate the useful from the obscure. The number of
recommended tags is 317.
Vertex M
Indication
Green
Red
Flashing
Green
Green (flashing)
Red
Red (flashing)
Off
Red
Red (flashing)
Red/Green (alternating)
Off
Green
Green (flashing)
Red (flashing)
Red/Green (alternating)
Off
Green
Communication running
Communication error
Network Interface Error
Initialized
Waiting for initialization
Major fault, unrecoverable
Minor fault, recoverable
Module not initialized
Major fault
Node configuration error
Hardware self test
Channel disabled
Normal operation
Temporary error or not configured
No other nodes or media fault
No connection has been opened
A connection has been opened
Table 8.18
244
Meaning
User Manual

Advertisement

Table of Contents
loading

Table of Contents