2.5 Analyzer Modules

The Vertex M system is populated with one or more types of analyzer modules. Each system
may contain Chemcassette™ modules or Pyrolyzer modules. Modules are installed in slots.
Tier 1
Chemcassette™ modules occupy one slot each. However, Pyrolyzer Chemcassette™ modules are
to be installed in slots 1 and 2. Pyrolyzer configuration and status information will appear in
slot 2.
Chemcassette™
Pyrolizer
Examples of possible combinations in a Vertex M system:
One, Two or Three Chemcassette™ modules
l
One pyrolyzer Chemcassette™ module
l
One pyrolyzer Chemcassette™ module, one Chemcassette™ module
l
The monitor will include only those modules specified at time of ordering.

2.6 Sampling System

Each Analyzer module is a monitoring center for sampling lines from sample locations. As they
apply to the Vertex M system, the words point, line and location require definition:
A location is a place to be monitored
l
Sample atmosphere runs from the location to the Vertex M system via a line
l
Each of the 24 sample tubing connections on the Vertex M system corresponds to a point. A
l
sample line can be connected directly to a single point or multiple points via a 4-port
manifold (PN: 1295-0349)
The system draws air simultaneously from all locations. Two different types of flow are:
Transport flow: high-velocity, large-volume air movement through the lines
l
Sample flow: air admitted to the Chemcassette™ detection system
l
Vertex M
CC
Slot 1
Table 2-1. Module Tier Structure
Number of
Points
8
1, 2 or 3
8
1 and 2 only
Table 2-2. Required Slots
CC
PYRO
Slot 2
Installed into
Total Possible per Vertex M sys-
Slots
3
1
25
CC
Slot 3
tem