NTP-G302 Connect the ONS 15454 Multishelf Node and
Subtending Shelves to a Catalyst 2950
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Using a cross-over (CAT-5) LAN cable, plug one connector into Port 1 of the active Catalyst 2950 and
Step 1
plug the other connector into the front panel of the node controller TCC2/TCC2P/TCC3 card in Slot 7.
Using a cross-over (CAT-5) LAN cable, plug one connector into Port 1 of the standby Catalyst 2950 and
Step 2
the other end into the front panel of the node controller TCC2/TCC2P/TCC3 card in Slot 11.
Step 3
Using a cross-over (CAT-5) LAN cable, plug one connector into Port 22 of the active Catalyst 2950 and
the other end into Port 22 of the standby Catalyst 2950.
Step 4
To connect a subtending shelf to the Catalyst 2950 switches, complete the following:
a.
b.
c.
Stop. You have completed this procedure.
78-19286-01
Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending
shelf TCC2/TCC2P/TCC3 card in Slot 11 and plug the other end into the SSC1 port on the right
EAP.
Repeat Steps
a
and
b
for each subtending shelf in the multishelf configuration. Use the same SSC
port number (2 through 8) on the left and right EAP for each subtending shelf.
Use this procedure to connect a multishelf node and subtending shelves to
two Cisco Catalyst 2950s and configure the Cisco Catalyst 2950.
Two Cisco Catalyst 2950 switches must be installed in same rack as the
node controller shelf; refer to the Cisco Catalyst 2950 product
documentation for installation instructions.
Cross-over (CAT-5) LAN cables (3, plus 2 for each subtending shelf)
NTP-G15 Install the Common Control Cards, page 1-74
(Optional)
As needed
Onsite
None
Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending
shelf TCC2/TCC2P/TCC3 card in Slot 7 and plug the other end into Port 2 of the active Catalyst
2950.
Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending
shelf TCC2/TCC2P/TCC3 card in Slot 11 and plug the other end into Port 2 of the standby
Catalyst 2950.
Repeat Steps
a
and
b
for each subtending shelf in the multishelf configuration using Ports 3
through 8 on the Catalyst 2950 switches.