Install the Cisco ONS 15454 Shelf Assembly
NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only)
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Voltage is present on the backplane when the system is operating. To reduce risk of an electric shock,
Warning
keep hands and fingers out of the power supply bays and backplane areas. Statement 166
Caution
Always use the supplied ESD wristband when working with a powered ONS 15454 ETSI. For detailed
instructions on how to wear the ESD wristband, refer to the
and Grounding
Note
The ONS 15454 ETSI EFCA has 12 FMEC slots numbered sequentially from left to right beginning with
Slot 18. Slots 18 to 22 and 25 to 29 provide electrical connections for the corresponding slots, so they
are unnecessary in DWDM applications.
Ensure that you are installing the FMECs in the correct slot:
Step 1
Hold the FMEC by the faceplate.
Step 2
Slide the FMEC along the guide rails into the desired FMEC slot or slots.
Step 3
Push the FMEC gently into the connector. The ONS 15454 ETSI FMECs plug into electrical connectors
Step 4
on the back panel of the shelf assembly when the screws are tightened.
installation.
78-19286-01
This procedure installs the MIC-A/P and the MIC-T/C/P FMECs in the
EFCA. The EFCA is located at the top of the ONS 15454 ETSI shelf. It
provides connection for installing power, external alarms, timing input and
output, and craft interface terminals.
#2 Phillips Dynamometric screwdriver
Medium slot-head screwdriver
Small slot-head screwdriver
FMECs (the MIC-A/P and MIC-T/C/P)
NTP-G4 Open and Remove the FMEC Cover (ETSI Only), page 1-26
Required
Onsite
None
Guide.
FMEC Slot 23 supports the MIC-A/P.
The MIC-A/P card provides connection for the BATTERY B input, one of the two possible
redundant power supply inputs. It also provides connection for eight alarm outputs (coming from
the TCC2/TCC2P/TCC3 card), sixteen alarm inputs, and four configurable alarm inputs/outputs.
FMEC Slot 24 supports the MIC-C/T/P.
The MIC-C/T/P card provides connection for the BATTERY A input, one of the two possible
redundant power supply inputs. It also provides connection for system management serial port,
system management LAN port, and system timing inputs and outputs.
Required Tools and Equipment (ETSI)
Cisco ONS Electrostatic Discharge (ESD)
Figure 1-15
Cisco ONS 15454 DWDM Procedure Guide, Release 9.2
shows FMEC
1-31