Chapter 1
Install the Cisco ONS 15454 Shelf Assembly
Table 1-3
DB-62 Pin Connector
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
Connect the other end of the alarm and control wires according to local site practice.
Step 2
Connect the DB-62 connector to the ALARM IN/OUT connector on the MIC-A/P faceplate.
Step 3
Tighten the screws of the connector on the alarm cable.
Step 4
Return to your originating procedure (NTP).
Step 5
78-19286-01
Alarm Pin Assignments (continued)
Signal Name
EXALM10+
EXALM11–
EXALM11+
ALMOUP0–
ALMOUP0+
FGND
ALMOUP1–
ALMOUP1+
ALMOUP2–
ALMOUP2+
ALMOUP3–
ALMOUP3+
AUDALM0–
AUDALM0+
AUDALM1–
AUDALM1+
AUDALM2–
AUDALM2+
FGND
AUDALM3–
AUDALM3+
VISALM0–
VISALM0+
VISALM1–
VISALM1+
VISALM2–
VISALM2+
VISALM3–
VISALM3+
Required Tools and Equipment (ETSI)
Function
Extra alarm 10
Extra alarm 11
Extra alarm 11
Normally open output pair number 1
Normally open output pair number 1
Ground
Normally open output pair number 2
Normally open output pair number 2
Normally open output pair number 3
Normally open output pair number 3
Normally open output pair number 4
Normally open output pair number 4
Normally open minor audible alarm
Normally open minor audible alarm
Normally open major audible alarm
Normally open major audible alarm
Normally open critical audible alarm
Normally open critical audible alarm
Ground
Normally open remote audible alarm
Normally open remote audible alarm
Normally open minor visible alarm
Normally open minor visible alarm
Normally open major visible alarm
Normally open major visible alarm
Normally open minor visible alarm
Normally open minor visible alarm
Normally open minor visible alarm
Normally open minor visible alarm
Cisco ONS 15454 DWDM Procedure Guide, Release 9.2