Cisco ONS 15454 Series Procedure Manual page 137

Dwdm
Hide thumbs Also See for ONS 15454 Series:
Table of Contents

Advertisement

Chapter 1
Install the Cisco ONS 15454 Shelf Assembly
Always use the supplied ESD wristband when working with a powered ONS 15454 ETSI. For detailed
Caution
instructions on how to wear the ESD wristband, refer to the
and Grounding
Step 1
For an ONS 15454 ETSI shelf, complete the following tasks as necessary:
For an ONS 15454 ANSI shelf, complete the following tasks as necessary:
Step 2
Stop. You have completed this procedure.
DLP-G20 Install Alarm Wires on the MIC-A/P (ETSI Only)
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
78-19286-01
Guide.
Complete the
"DLP-G20 Install Alarm Wires on the MIC-A/P (ETSI Only)" task on page 1-49
you want to provision external alarms and/or controls with the AIC-I card.
Complete the
"DLP-G21 Install Timing Wires on the MIC-C/T/P (ETSI Only)" task on page 1-52
you are provisioning external timing.
Complete the
"DLP-G22 Install LAN Wires on the MIC-C/T/P (ETSI Only)" task on page 1-53
create an external LAN connection. You must either install LAN wires on the MIC-C/T/P or connect
a CAT-5 Ethernet cable to the LAN port on the TCC2/TCC2P/TCC3 card to create an external LAN
connection.
Complete the
"DLP-G23 Install Alarm Wires on the Backplane (ANSI Only)" task on page 1-54
you are using an AIC-I card and are not using an AEP.
Complete the
"DLP-G24 Install Timing Wires on the Backplane (ANSI Only)" task on page 1-56
you are provisioning external timing.
Complete the
"DLP-G25 Install LAN Wires on the Backplane (ANSI Only)" task on page 1-57
create an external LAN connection. You must either install LAN wires on the backplane or connect
a CAT-5 Ethernet cable to the LAN port on the TCC2/TCC2P/TCC3 card to create an external LAN
connection.
Complete the
"DLP-G26 Install the TL1 Craft Interface Wires (ANSI Only)" task on page 1-58
access Transaction Language One (TL1) using the craft interface. Craft wires or the EIA/TIA-232
port on the TCC2/TCC2P/TCC3 card are required to access TL1.
This task installs alarm cables on the MIC-A/P on the ONS 15454 ETSI so
that you can provision external (environmental) alarms and controls with
the AIC-I card.
DB-62 connector
0.51 mm² or 0.64 mm² (#22 or #24 AWG) wires
NTP-G6 Install the MIC-A/P and MIC-T/C/P FMECs (ETSI Only),
page 1-31
As needed
Onsite
None
Required Tools and Equipment (ETSI)
Cisco ONS Electrostatic Discharge (ESD)
Cisco ONS 15454 DWDM Procedure Guide, Release 9.2
if
if
to
if
if
to
to
1-49