Climate Control
DTC Troubleshooting (cont'd)
8. Check for continuity between climate control unit
connector A (28P) No. 25 terminal and the sunlight
sensor 5P connector No. 4 terminal (with automatic
lighting) or the sunlight sensor 2P connector No. 1
terminal (without automatic lighting).
With automatic lighting
*01
CLIMATE CONTROL UNIT CONNECTOR A (28P)
*1: With navigation
*2: Without navigation
Without automatic lighting
*02
CLIMATE CONTROL UNIT CONNECTOR A (28P)
*1: With navigation
*2: Without navigation
Is there continuity?
YES
NO
−
control unit and the sunlight sensor.
21-124
Wire side of female terminals
PUR
SUNLIGHT SENSOR 5P CONNECTOR
Wire side of female terminals
Wire side of female terminals
PUR
SUNLIGHT SENSOR 2P CONNECTOR
Wire side of female terminals
−
Go to step 9.
Repair open in the wire between the climate
9. Check for continuity between climate control unit
connector B (12P) No. 10 terminal and the sunlight
sensor 5P connector No. 2 terminal (with automatic
lighting) or the sunlight sensor 2P connector No. 2
terminal (without automatic lighting).
With automatic lighting
CLIMATE CONTROL UNIT CONNECTOR B (12P)
1
YEL*
2
PUR*
*1: With navigation
*2: Without navigation
Without automatic lighting
CLIMATE CONTROL UNIT CONNECTOR B (12P)
1
YEL*
2
PUR*
*1: With navigation
*2: Without navigation
Is there continuity?
YES
−
NO
−
control unit and the sunlight sensor.
Wire side of female terminals
1
WHT*
2
RED*
RED
SUNLIGHT SENSOR 5P CONNECTOR
Wire side of female terminals
Wire side of female terminals
1
WHT*
2
RED*
RED
SUNLIGHT SENSOR 2P CONNECTOR
Wire side of female terminals
Go to step 10.
Repair open in the wire between the climate
*03
*04