12. Check for continuity between the driver's power
window motor 6P connector No. 6 terminal and
body ground.
*02
DRIVER'S POWER WINDOW MOTOR 6P CONNECTOR
Is there continuity?
YES
NO
13. Test the driver's power window motor (see page
22-276).
Is the motor OK ?
YES
NO
14. Check for continuity between the driver's power
window motor 6P connector No. 2 terminal and
body ground.
*03
DRIVER'S POWER WINDOW MOTOR 6P CONNECTOR
Is there continuity?
YES
NO
(G501).
22-258
PLSA (PNK)
Wire side of female terminals
Repair a short to ground in the wire.
Go to step 13.
Replace the power window master switch.
Replace the driver's power window motor.
GND (BLK)
Wire side of female terminals
Go to step 15.
Repair an open in the wire or poor ground
15. Check for continuity between the door multiplex
control unit 37P connector No. 3 terminal and the
driver's power window motor 6P connector No. 5
terminal.
DOOR MULTIPLEX CONTROL UNIT 37P CONNECTOR
Wire side of female terminals
SVCC (PUR)
SVCC (PUR)
DRIVER'S POWER WINDOW MOTOR 6P CONNECTOR
Wire side of female terminals
Is there continuity?
YES
Go to step 16.
NO
Repair an open in the wire.
16. Check for continuity between the driver's power
window motor 6P connector No. 5 terminal and
body ground.
DRIVER'S POWER WINDOW MOTOR 6P CONNECTOR
SVCC (PUR)
Wire side of female terminals
Is there continuity?
YES
Repair a short to ground in the wire.
NO
Replace the driver's power window motor.