07/11/02 09:42:27 61TA0000_220_0356
5. With the connector still disconnected, make these input tests at the connector.
• If any test indicates a problem, find and correct the cause, then recheck the system.
• If all the input tests prove OK, go to step 6.
Cavity
11
Wire
Test condition
BLU
Under all
Check for continuity between the
conditions
moonroof switch 14P connector
No. 11 terminal and power
window master switch 37P
connector No. 27 terminal:
There should be continuity.
Check for continuity between the
moonroof switch 14P connector
No. 11 terminal and body ground:
There should be no continuity.
Test: Desired result
Possible cause if desired result
An open in the wire
A short to ground in the wire
is not obtained
(cont'd)
22-353