Section D - Control And Management Interfaces; Ethernet Management Interface; Rs-232 Data Interface; Alarm Interface - Cisco PowerVu D9858 Installation And Operation Manual

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Section D - Control and Management Interfaces

Ethernet Management Interface

Number of connectors
Type of connector
Ethernet type
Required setup

RS-232 Data Interface

Connector type
Data rates

Alarm Interface

Number of outputs
Type of connector
Max. voltage
Max. current

Contact Closure Interface

Connector type
Minimum duration of event
guaranteed to be detected
Max. on generator impedance
Min. off generator impedance
A-12
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Item
Item
Item
Item
Specification
1
Eight-pin RJ-45
10/100 BaseT
IP address, default gateway and subnet
mask
Specification
9-pin sub-D female
RS-232 asynchronous data at selectable
rates up to 38.4 kb/s: 300, 1200, 2400, 4800,
9600, 19,200, 38,400 b/s
Specification
3, each having one set of contacts closed
and one set open during normal operation.
Alarms are signalled by reversing the
polarity of the two contact sets.
Terminal block
≤ 30 V AC, ≤ 30 V DC
≤ 1 A
Specification
9-pin sub-D female
250 ms, 1 frame period, e.g., for 1080i/25
Hz, 40 ms for DPI applications
100 Ω
100 kΩ