Cisco PowerVu D9858 Installation And Operation Manual page 149

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Alarm
Message
Type
FPGA
Set
Temperature
Alarm
Clear
Output Muted
Set
Clear
ASI Out Status
MPoIP Status
4023074 Rev B
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Message
Temperature over
Alarm threshold
Clear Temperature
Alarm
ASI Overflow.
Output Muted.
Reduce content.
MPEGoIP Overflow.
Output Muted.
Reduce content.
ASI Output Restored
MPEGoIP Output
Restored
ASI Out Status
MPoIP Status
Cause/Remedy
Cause: Room
temperature too high,
or air flow is blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature or
improve air flow to
device.
Cause: Uplink
settings may have
changed since setting
up the unit. Variable
Bit Rate/Statmuxed
streams may be in
use.
Remedy: Increase
output rate, drop
unreferenced content
in DPM Options,
drop programs not
needed for
downstream devices.
Contact your service
provider (uplink) to
verify expected bit
rate settings.
Description
Severity
FPGA
Major
temperature is
above safe
operating range.
Current
Minor
transport rate
exceeds
configured rate
for ASI output.
Output has been
muted to protect
downstream
devices.
Current
transport rate
exceeds
configured rate
for MPEG over
IP output.
Output has been
muted to protect
downstream
devices.
Minor
Minor