Cisco PowerVu D9858 Installation And Operation Manual page 154

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Warning
Transport ErrorSet
Video Format
Mismatch
Temperature
Warning
5-14
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Message
Message
Type
Set
Continuity Count
Error
Buffer Overflow
Transport Error
Indicator
Transport Rate Error:
FPGA Overflow
Clear
Continuity Count
Error ClearedClear
Buffer Overflow
Cleared
Transport Error
Indicator Cleared
Transport Rate Error:
FPGA Overflow
Cleared
Video Format
Mismatch
Set
Temperature over
Warning threshold
Clear
Clear Temperature
Warning
Cause/Remedy
Cause: Possible uplink or
signal issue.
Remedy: Clear warnings,
reset unit, and notify
customer service if problem
persists.
Cause: Uplink settings may
have changed since setting
up the unit. Variable Bit
Rate/Statmuxed streams
may be in use.
Remedy: Increase output
rate, drop unreferenced
content in DPM Options,
drop programs not needed
for downstream devices.
Contact uplink to verify
expected bitrate settings.
Cause: Room temperature
too high, or air flow is
blocked.
Remedy: Check openings
on front and rear panels for
blockage. Lower the room
temperature or improve air
flow to device.
Description
Transport packet
continuity count
jumped. Possible
packet loss.
The transport stream
is faster than the
maximum buffer or
the decode engines
are having difficulty
handling the data
sent to them.
Transport packets are
marked as "errored"
upstream of the
decoder.
The output rate is
higher than level set
by the user.
Trap expires after 30
seconds.
Temperature is above
normal operating
range.
4023074 Rev B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents