Cisco PowerVu D9858 Installation And Operation Manual page 146

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Alarm
Message
Type
PE n: Loss of
Set
Input
Clear
Digital Program
Set
Mapping
Clear
Shutdown
SMI Setup
Set
Clear
5-6
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Message
Loss of input
detected
Fault reset
PID Collision
Program Collision
Mode-i PMT out of
range
Digital Program
Mapping - OK
Shutdown Event
Phase lock error on
SMI SDRAM
SMI SDRAM exhaust
test failed
SMI SDRAM setup
successful
SMI SDRAM exhaust
test passed
Cause/Remedy
Cause: Loss of input.
Remedy: Ensure
input has a valid
stream.
Cause: Uplink
settings may have
changed since setting
up the unit. Please
check your DPM
settings.
Remedy: Correct
DPM settings. Check
the uplink to find
appropriate system
settings.
Cause: Hardware
Issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Description
Severity
Loss of input.
Minor
Two source
Minor
service PIDs are
being mapped to
the same output
PID. This will
cause data
corruption in the
stream.
Two source
channel numbers
are being
mapped/passed
to the same
channel number
in the output.
PMT PID to be
used for Mode-i
is outside of
valid MPEG PID
range.
Major
SDRAM on SMI
Major
bus not working.
SDRAM on SMI
Bus OK.