Cisco PowerVu D9858 Installation And Operation Manual page 156

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Warning
PAT timeout
NIT timeout
CAT timeout
DRT timeout
5-16
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Message
Message
Type
Set
pat # timed out
pat # is lost
Clear
pat fault cleared
Set
nit timed out
nit is lost
Clear
nit fault cleared
Set
cat timed out
cat is lost
Clear
cat fault cleared
Set
drt # timed out
drt # is lost
Clear
drt fault cleared
Cause/Remedy
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Description
Program Association
Table was never
received.
No longer receiving
Program Association
Table.
Network Information
Table was never
received.
No longer receiving
Network Information
Table.
Conditional Access
Table was never
received.
No longer receiving
Conditional Access
Table.
Disaster Recovery
Table was never
received.
No longer receiving
Disaster Recovery
Table.
4023074 Rev B