Cisco PowerVu D9858 Installation And Operation Manual page 147

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Alarm
Message
Type
LMI setup
Set
Clear
PARAM
Set
STORAGE
Clear
Flash STORAGE
Set
Clear
LNB PS
4023074 Rev B
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Message
LMI SDRAM exhaust
test failed
LMI Video SDRAM
exhaust test passed
DB NVS flushing
ignored
RAM flush to NVS
failed
DB Factory Reset
failed
DB flushing
completed
DB Factory Reset
completed
RECORD: init failed
RECORD
MANAGER: Record
contents check error,
erasing all
RECORD: sector
setup check error,
erasing sector
RECORD: init done
LNB PS
Cause/Remedy
Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Cause: Hardware
issue.
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists.
Description
Severity
DDR RAM on
Major
LMI bus not
working.
DDR RAM on
LMI bus OK.
Non-volatile
Major
storage system
failed to update
fully.
Non-volatile
storage system
failed during
factory reset.
Successful NVS
update.
Successful
action.
Non-volatile
Major
storage system
corrupted.
Possible loss of
configuration.
NVS Corruption,
and loss of
configuration
data
NVS Corruption,
and loss of sector
data
Minor
5-7