TRUNK GROUP BUSY DISPLAY

PROGRAMMING
START
CM30
Assign the trunk group number to each trunk.
Several trunks may be assigned to one trunk
group number.
CM90
For providing the Trunk Group Busy Lamps
on Attendant Console, assign the trunk group
number to required key.
NOTE 1:
NOTE 2:
CM44
For providing external Trunk Group Busy
Lamps, assign the trunk group number to the
required circuit number on the DK card or
circuit number of the external relay control on
the MP card.
END
HARDWARE REQUIRED
To provide the Trunk Group Busy Lamps externally:
DK card and lamp indicator provided by customer
DESCRIPTION
Maximum 6 keys per DESKCON
can be assigned. Any six trunk group
number out of trunk group number
01-62 can be assigned.
Key number 1-6 should not be
assigned to provide a Trunk Group
Busy Lamp.
Y=09
(1)
000-255: Trunk No.
(2)
01-62: Trunk Group No.
Y=00
(1)
ATTCON No. (E000-E007) +
No.
(2)
F12XX
XX: 01-62: Trunk Group No. assigned by
CM30 Y=09
(1)
XX Y
XX: 00-31: DK Card No. E800-E831
assigned by CM10/CM14
Y : 0-3: Circuit No.
313: Built-in DK on MP card
(2)
11XX
XX: 01-62: Trunk Group No. assigned by
CM30 Y=09
– 77 –
ATTENDANT CONSOLE
TRUNK GROUP BUSY DISPLAY
DATA
,
+ Key
NWA-008845-001 Rev.5.0