CM36
For an outside participant, allow tandem
connection between the conference trunk route
and the outgoing trunk route to the participant.
For an outside conference leader, allow
tandem connection between the incoming
trunk route from the conference leader and the
conference trunk route.
CM41
Specify the detect timing of participant's no
answer. The ringing will stop at this timing.
CM35
Assign a trunk name number for the confer-
ence trunk route not to display the kind of
trunk route assigned by CM35 Y=00 on a
term
D
.
"CNF GROUPxx" will be displayed on a D
of participant.
CM77
Assign the trunk name to "20" (space).
D
DESCRIPTION
Y=0
(1)
0000-6363: Conference Trunk Route No.
(2)
0: Allow
Y=0
(1)
0000-6363: Incoming Trunk Route No. +
(2)
0: Allow
Y=3
(1)
16
(2)
00
: No stop ringing
01-14: 1-14 minutes
If no data is set, the default setting is 30 seconds.
Y=03
(1)
00-63: Trunk Roue No.
(2)
00-14: Trunk Name No.
16-63: Trunk Name No.
term
Y=2 By Character Code
(1)
00-14, 16-63: Trunk Name No. assigned by
(2)
20: Space
– 236 –
CONFERENCE (32-PARTY)
GROUP CALL
DATA
assigned by CM30 Y=00 +
Outgoing Trunk Route No.
Conference Trunk Route No.
assigned by CM30 Y=00
(1 minute increments)
CM35 Y=03