DIRECT INWARD TERMINATION (DIT)

PROGRAMMING
START
CM30
Assign the data for terminating system in Day
Mode/Night Mode/Mode A/Mode B, to each
Loop/Ground Start trunk, respectively.
Assign the station number to be terminated by
DIT in Day Mode/Night Mode/Mode A/Mode
B respectively.
Assign the destination to be rerouted when the
DIT station is busy/not available in Day Mode
and Night Mode respectively.
Assign the transfer destination for an unan-
swered DIT call in Day Mode and Night Mode,
respectively.
CM41
Specify the timing for an unanswered call to a
DIT destination.
CM08
Assign the ring cadence on a DIT call.
END
DESCRIPTION
DIRECT INWARD TERMINATION (DIT)
Y=02 Day Mode/03 Night Mode/
40 Mode A/41 Mode B
(1)
000-255: Trunk No.
(2)
04: Direct-In Termination
Y=04 Day Mode/05 Night Mode/
42 Mode A/43 Mode B
(1)
000-255: Trunk No.
(2)
X-XXXXXXXX: Station No.
Y=13 Day Mode/14 Night Mode
(1)
000-255: Trunk No.
(2)
01 : TAS BUZZER
04 : Attendant Console
06 : Automatic Camp-On
15 : Waiting until the DIT station be-
comes idle
Y=15 Day Mode/16 Night Mode
(1)
000-255: Trunk No.
(2)
01 : Attendant Console
03 : TAS
15 : To be continued DIT
Y=0
(1)
01
(2)
01-30: 4-120 seconds
If no data is set, the default setting is 32-36
seconds.
(1)
179
(2)
0 : As per CM35 Y=33
1 : 0.4 seconds ON-0.2 seconds OFF-0.4
seconds ON-2 seconds OFF
[For North America]
Special Ringing
(See
CM08>392/CM08>396/
CM08>397.
[For EU]