TIMED FORCED RELEASE

[Series 3500 software required]
PROGRAMMING
START
CM35
Provide the outgoing trunk route with forced
release in designated time.
Provide the incoming trunk route with forced
release in designated time.
CM41
Specify the warning SST sending timer for
forced release, Timer A, B and C respectively.
NOTE:
CM12
Specify the warning SST sending timer for
forced release to the required stations.
NOTE:
A
DESCRIPTION
Set the time from the start of commu-
nications to the warning SST is sent.
Forced release is executed at 16 sec-
onds later from the warning SST is
sent.
This data is effective when the
forced release is provided to the des-
tination trunk route (CM35 Y=247
and CM35 Y=248 is set to 0).
Y=247
(1)
00-63: Trunk Route No.
(2)
0 : To provide
1 : Not provided
Y=248
(1)
00-63: Trunk Route No.
(2)
0 : To provide
1 : Not provided
Y=0
(1)
114: Timer A
115: Timer B
116: Timer C
(2)
01-99: 64-6336 seconds
(64 second increments)
NONE : No data
Y=61
(1)
X-XXXXXXXX: Station No.
(2)
0 : Depends on Timer A
1 : Depends on Timer B
2 : Depends on Timer C
3 : Forced Release is not provided
– 698 –